Ozone Contact Skid Systems

Ozone Contact Skid Systems
Ozone Generator Skid Swimming Pool System

Ozone Generator – Contact Skid System for Swimming Pools & Waterparks

MAT decided to design ozone contact skids from scratch. Our equipment derived after spending more than 3 years in Research &Development and field trials. Generally, it was considered that providing a standard pressurized chamber for the O3 to be infused in water was enough.

Disinfection is a key component to the multi-barrier approach to provide safe swimming water. The most effective disinfection is demonstrated through the concept of contact time (CT), which is defined as a product of a disinfectant residual concentration(C), in mg/L and the effective disinfectant contact time (T), in minute. The CT value is developed to relate the level of inactivation under different operational conditions.

Depending on the treatment processes, additional Crypto and Giardia removal/inactivation may be required for a surface water source. Significant deterioration of water quality may require further removal or inactivation of virus, Cryptosporidium, and Giardia.

MAT Ozone Contact Skids (OCS) designed as per best contact time for each purpose of the application. MAT Ozone Contact Skids have its own booster pump to pressurize water in contact tank to maximize solubility efficiency. MAT Ozone Contact Skids has also an ozone destruct unit as default on skid for safety regulations.

Ozone Contact Skid Systems - SPECIFICATIONS

Fresh Water

ModelContact Tank Diameter (mm) Foot Print (mm) Foot Print (mm)Max. Height (mm)Treatment Flowrate
(m³/h)
Contact Time (min)Ozone Concentration (PPM)Ozone Dosing (g/h)CT ValuePower Consumption (kW)Booster Pump MaterialPump Variable Frequency DriverElectrical Control BoardDigital Flow MonitoringPLC ControlDO3 ProbeORP Probe
OCS-F-52001100105025002.5525103.7SS316 DANFOSS / HIGH IP RATING50/60 Hz.Chemical Resistant Sensor & TransmitterSIEMENSJumoJumo
OCS-F-1054012501050250055210104.1SS316 DANFOSS / HIGH IP RATING51/60 Hz.Chemical Resistant Sensor & TransmitterSIEMENSJumoJumo
OCS-F-20980142010502600105220105.2SS316 DANFOSS / HIGH IP RATING52/60 Hz.Chemical Resistant Sensor & TransmitterSIEMENSJumoJumo
OCS-F-301590170012002700155230105.2SS316 DANFOSS / HIGH IP RATING53/60 Hz.Chemical Resistant Sensor & TransmitterSIEMENSJumoJumo
OCS-F-502360270013502800255250107SS316 DANFOSS / HIGH IP RATING54/60 Hz.Chemical Resistant Sensor & TransmitterSIEMENSJumoJumo
OCS-F-75332029002000290037.55275108.5SS316 DANFOSS / HIGH IP RATING55/60 Hz.Chemical Resistant Sensor & TransmitterSIEMENSJumoJumo
OCS-F-100446030502150300050521001014SS316 DANFOSS / HIGH IP RATING56/60 Hz.Chemical Resistant Sensor & TransmitterSIEMENSJumoJumo
OCS-F-150460032002200315075521501015.5SS316 DANFOSS / HIGH IP RATING57/60 Hz.Chemical Resistant Sensor & TransmitterSIEMENSJumoJumo
OCS-F-2004600320022003150100522001015.5SS316 DANFOSS / HIGH IP RATING58/60 Hz.Chemical Resistant Sensor & TransmitterSIEMENSJumoJumo
OCS-F-2504700325023503275125522501017SS316 DANFOSS / HIGH IP RATING59/60 Hz.Chemical Resistant Sensor & TransmitterSIEMENSJumoJumo

Salt Water

ModelContact Tank Diameter (mm) Foot Print (mm) Foot Print (mm)Max. Height (mm)Treatment Flowrate
(m³/h)
Contact Time (min)Ozone Concentration (PPM)Ozone Dosing (g/h)CT ValuePower Consumption (kW)Booster Pump MaterialPump Variable Frequency DriverElectrical Control BoardDigital Flow MonitoringPLC ControlDO3 ProbeORP Probe
OCS-F-52001100105025002.5525103.8Titanium DANFOSS / HIGH IP RATING50/60 Hz.Chemical Resistant Sensor & TransmitterSIEMENSJumoJumo
OCS-F-1054012501050250055210103.8Titanium DANFOSS / HIGH IP RATING51/60 Hz.Chemical Resistant Sensor & TransmitterSIEMENSJumoJumo
OCS-F-20980142010502600105220105.2Titanium DANFOSS / HIGH IP RATING52/60 Hz.Chemical Resistant Sensor & TransmitterSIEMENSJumoJumo
OCS-F-301590170012002700155230105.2Titanium DANFOSS / HIGH IP RATING53/60 Hz.Chemical Resistant Sensor & TransmitterSIEMENSJumoJumo
OCS-F-502360270013502800255250106Titanium DANFOSS / HIGH IP RATING54/60 Hz.Chemical Resistant Sensor & TransmitterSIEMENSJumoJumo
OCS-F-75332029002000290037.55275107Titanium DANFOSS / HIGH IP RATING55/60 Hz.Chemical Resistant Sensor & TransmitterSIEMENSJumoJumo
OCS-F-100446030502150300050521001014Titanium DANFOSS / HIGH IP RATING56/60 Hz.Chemical Resistant Sensor & TransmitterSIEMENSJumoJumo
OCS-F-150460032002200315075521501015.5Titanium DANFOSS / HIGH IP RATING57/60 Hz.Chemical Resistant Sensor & TransmitterSIEMENSJumoJumo
OCS-F-2004600320022003150100522001015.5Titanium DANFOSS / HIGH IP RATING58/60 Hz.Chemical Resistant Sensor & TransmitterSIEMENSJumoJumo
OCS-F-2504700325023503275125522501017Titanium DANFOSS / HIGH IP RATING59/60 Hz.Chemical Resistant Sensor & TransmitterSIEMENSJumoJumo
* MAT FILTRATION TECHNOLOGIES™ preserves the right to update anytime the listed prices (if any). Every effort has been made so that the above specs are accurate. However please contact our Sales Department for up to date technical data, electrical specs according to your regional requirements and current Ex-Works pricelist. The listed prices are for the basic equipment and do not include any optional components.